21 Jul 2022

Checklist of Beam & column Reinforcement Bar

​1. Physical Appearance of the bar at.

2. Grade of steel as per drawing 

3. Cover Block of Beam and Column and its size

4. Diameter of bar and stirrups and its spacing.

5. Hook length and its angle 

6. Through Bar and Extra Bar exact length and fencing with double binding wire.

7. Proper Lapping length as per the diameter of bar.



13 Jul 2022

preparations before column cating after plinth Beam




straper

Local name ticker is used before casting column 

Some of the important points which helps to casting column

​1. Proper cover between steel rod and formwork.

2. Maintain vertically between plinth beam to slab beam 

3. Grid gapping corrected the position of column is used in a exact line 



12 Jul 2022

Sizes of Cover Block Used Nepal

​1. Raft foundation bottoms/ sides : 50-75mm

2. Strap Beam: 35mm

3. Slab:15mm

4. Column: 40 mm

5. Shear wall:25mm

6. Flat slab: 20mm

7. Stair case : 15 mm

8. Retaining wall: 20/25 mm on earth

9. Water retaining structure: 20/30 mm

cover block used in columns

Types of cover Block

1. Steel cover block

2. PVC block

3. Cement masonry 

4. Aluminium cover

5. Stone 

Why Cover Block are used -Nepal

​Cover Block are used for following purposes 

1- To maintain distance between Rebar & shuttering.

2- To protect steel bar from environmental effect 

3- To prevent from corrosion.

4- To give sufficient embedding to enable them to be stressed without slipping.


cover block used in column casting

​Cover Block used in Column 

In order to used in the column normally nominal size of cover block is 40 mm but it depends upon size of the structure.

The cover blocks lifts the rebar up by about 20 mm to 75 mm and becomes a permanent and integral part of the poured concrete.

It ensure that no part of the rebar sags and minimizes that required concrete cover age during pouring of concrete.

Normally cover block should be used the following concrete stages in the Building 

1. footing Area 

2. Column 

3. Beam

4. Stair 

5. Slab 



Column casting

Formwork in column 



10 Jul 2022

Shear Wall and Column connections

Shear wall is the Reinforced concrete section which having cement sand aggregate and steel as per the design by the designer. Normally i have found 16 mm dai bar used in the residential building but commercial building have different designs.

Specially Lift portion of building have needed because of heavyweights of lift or as per design load minimum thickness of shear wall is 250mm and steel as per designer but minimum thickness of share wall steel diameter should not more than 16mm. 
Column and shear connection in this figure

धितोपत्र बोर्डले NEPSE Index मा लाग्ने सर्किट ब्रेकरको सिमा ६% बाट बढाएर ८% पुर्‍याएको छ ।